Polyanionic Cellulose can be used in drilling fluid, fixing fluid and fracturing fluid. In drilling fluid, it works as viscosifier, filtration reducer, and rheology controller; in fixing fluid, it is used to control fluid viscosity, suspend heavy objects, and avoid fluid loss; in fracturing fluid, it is used to carry stuffing and avoid fluid loss. It meets API international standard.
Specification
Technical Specifications of PAC | |||||||||||
Item/Type | PAC-SH*LV | PAC-SLV | PAC-MLV | PAC-LV | PAC-HLV | PAC-GLV
(Granular) |
PAC-SHV | PAC-MHV | PAC-HV | PAC-HHV | PAC-GHV
(Granular) |
Purity(%) | ≥65.0 | ≥65.0 | ≥85.0 | ≥95.0 | ≥98.0 | ≥95.0 | ≥75.0 | ≥85.0 | ≥95.0 | ≥98.0 | ≥95.0 |
Apparent
Viscosity(mPa•s) |
≤40 | ≤40 | ≤40 | ≤40 | ≤40 | ≤40 | ≥35 | ≥50 | ≥50 | ≥50 | ≥50 |
Fluid Loss (FL),(mL) | ≤12 | ≤16 | ≤16 | ≤16 | ≤16 | ≤16 | ≤23 | ≤23 | ≤23 | ≤23 | ≤23 |
Loss on Drying(%) | ≤10.0 | ≤12.0 | ≤10.0 | ≤12.0 | |||||||
Degree of Substitution | ≥0.90 | ||||||||||
pH Value(1%) | 6.5-9.0 | ||||||||||
Remarks | SH* is High-temperature resistant product
Conforms to API Spec. 13A standard |
High-Performance Polyanionic Cellulose
Type | Purity(%) | Brookfield LVT/25℃
Viscosity(mPa•s) |
Properties |
PL-30000
Extremely high Viscosity |
98 | Min2500 | *A fluid loss agent with a very high yield
*An excellent viscosifier *With shale inhibiting properties |
PL-100
Low Viscosity |
98 | 80-160 | *A fluid loss agent with a good yield and also extremely good rheological properties for low filtration values |
PL-30
Ultra Low Viscosity |
98 | 20-60 | *A fluid loss agent for extremely low filtration values
*No disturbing increase in viscosity |
Sodium Carboxymethyl Cellulose
Overview
Sodium Carboxymethyl Cellulose is a high quality water soluble cellulose derivative. It has good thermal-stability and high salt resistance. It is soluble in water to form thick liquid, and widely used in water-base drilling fluid so as to enhance the drilling fluid viscosity and control the fluid loss.
Specification
Technical Specifications of CMC-HV&CMC-LV | |||
Specifications Type | CMC-HV | CMC-LV | |
Viscometer dial reading at 600r/min. | In distilled water | ≥30 | ≤90 |
In 40g/L salt water | ≥30 | ||
In saturated salt water | ≥30 | ||
Fluid Loss(ml) | ≤10.0 | ≤10 | |
Remarks | Conforms to API Spec. 13A Standard |